The 6G Seismic Network, 2017–2018

 
Cite as:
Toledo, Tania; Gaucher, Emmanuel; Metz, Malte; Calò, Marco; Figueroa, Angel; Angulo, Joel; Jousset, Philippe; Kieling, Katrin; Saenger, Erik (2019): Dataset of the 6G seismic network at Los Humeros, 2017-2018. GFZ Data Services. Other/Seismic Network. doi:10.14470/1T7562235078.
Network code:
6G
Type:
Temporary
Network dates:
2017-07-20 to 2018-12-31
Data time range:
2017–2018
Terms of use:
Creative Commons Attribution 4.0 InternationalCC-BY-4.0 Available since 2023-01-01
Institution(s):
Deutsches GeoForschungsZentrum GFZ, Karlsruhe Institute of Technology KIT, Instituto de Geofísica (UNAM), Universidad Michoacana de San Nicolás de Hidalgo, Hochschule Bochum (HBO)
Creator(s):
Toledo, Tania; Gaucher, Emmanuel; Metz, Malte; Calò, Marco; Figueroa, Angel; Angulo, Joel; Jousset, Philippe; Kieling, Katrin; Saenger, Erik (LEGACY)
Description*:
Dataset of the 6G seismic network at Los Humeros, 2017-2018
Abstract:
Extensive passive seismic monitoring was carried out between September 2017 and September 2018 over the Los Humeros geothermal field in Mexico. This experiment, in addition to several geophysical, geological, and geochemical surveys was conducted in the framework of the European H2020 and Mexican CONACyT-SENER project GEMex for a better understanding of the structures and behavior of the local geothermal system currently under exploitation, and for investigating future development areas. 25 broadband stations (22 Trillium C-120s and 3 Trillium C-20 PH) recording at 200 Hz, and 20 short period stations (Mark L-4C-3D) recording at 100 Hz comprised the network which is sub-divided into two sub-networks. An inner and denser (~1.6-2 km inter-station distance) pseudo-rhomboidal array (27 stations) was laid out to cover the producing zone and retrieve local seismicity mainly associated to injection and production operations, and to comply with beamforming of ambient noise and time reverse imaging techniques. An outer and sparser (~5 km minimum spacing) array was placed at around 30 km radius surrounding the inner network, and was mainly dedicated to larger scale imaging techniques, such as seismic ambient noise tomography, and regional earthquakes tomography. The GEMex project is supported by the European Union’s Horizon 2020 programme for Research and Innovation under grant agreement No 727550 and the Mexican Energy Sustainability Fund CONACYT-SENER, project 2015-04-68074.

* Description is taken from seismic metadata, and may not match the preferred title for citations.
DataCite metadata:
HTML | JSON | XML | INSPIRE
Seismic metadata:
fdsnws-station
Sponsor:
Geophysical Instrument Pool Potsdam (GIPP)
Funder:
European Union’s Horizon 2020 programme for Research and Innovation (grant agreement No 727550); Mexican Energy Sustainability Fund CONACYT-SENER (project 2015-04-68074)
Network KML file:
To retrieve waveform data and metadata (including instrument responses) for this and other seismic networks, see here.

Extended Network Information for network 6G [hide/show]

Creator(s):
orcid:0000-0002-6870-2194 Toledo, Tania a; orcid:0000-0001-5870-4113 Gaucher, Emmanuel b; orcid:0000-0002-9912-5502 Metz, Malte a; orcid:0000-0001-7261-7008 Calò, Marco c; orcid:0000-0001-8464-0117 Figueroa, Angel d; Angulo, Joel c; orcid:0000-0002-5628-0238 Jousset, Philippe a; orcid:0000-0003-0182-5090 Kieling, Katrin a; orcid:0000-0002-2057-4728 Saenger, Erik e
a Deutsches GeoForschungsZentrum, Potsdam, Germany, b Karlsruhe Institute of Technology KIT, Geophysical Institute GPI, Karlsruhe, Germany, c Instituto de Geofísica, UNAM, Mexico, d Universidad Michoacana de San Nicolás de Hidalgo, UMSNH, Mexico, e Hochschule Bochum (HBO), Bochum, Germany
Title:
Dataset of the 6G seismic network at Los Humeros, 2017-2018
Publisher:
GFZ Data Services
Resource Type:
Other/Seismic Network
Network DOI:
doi:10.14470/1T7562235078
Related Reference(s):
  1. Finger, C.; Saenger, E. H. (2020). Sensitivity maps for time-reverse imaging: an accuracy study for the Los Humeros Geothermal Field (Mexico). Geophysical Journal International, Volume 222, Issue 1, July 2020, Pages 231-246. doi:10.1093/gji/ggaa160
  2. Granados, I.; Calò, M.; Figueroa, A.; Jousset, P. (2020). 3D Anisotropic velocity model of the Los Humeros geothermal field, Mexico, using seismic ambient noise tomography. EGU General Assembly 2020, Vienna, Austria.
  3. Löer, K.; Toledo, T.; Norini, G.; Zhang, X.; Curtis, A.; Saenger, E. H. (2020). Imaging the deep structures of the Los Humeros geothermal field, Mexico, using three-component ambient noise beamforming. Seismological Research Letters (2020) 91 (6): 3269-3277. doi:10.1785/0220200022
  4. Toledo, T.; Gaucher, E.; Jousset, P.; Jentsch, A.; Haberland, C.; Maurer, H.; Krawczyk, C.; Calò, M.; Figueroa, A. (2020). Local earthquake tomography at Los Humeros geothermal field (Mexico). Journal of Geophysical Research: Solid Earth, 125. doi:10.1029/2020JB020390
  5. Gaucher, Emmanuel; Toledo, Tania; Metz, Malte; Figueroa-Soto, Angel G.; Calò, Marco (2019). One year of passive seismic monitoring of the Los Humeros (Mexico) geothermal field. European Geothermal Congress 2019. Den Haag, The Netherlands, 11-14 June 2019.
  6. Verdel, A.; Boullenger, B.; Martins, J.; Obermann, A.; Toledo, T.; Jousset, P. (2019). Ambient noise seismic reflection interferometry at the Los Humeros geothermal field, Mexico. Proceedings of the European Geothermal Congress 2019, Den Haag, The Netherlands.
[+] To provide additional references, PIs should contact GEOFON staff.
Place(s):
Los Humeros, Mexico
Subject(s)a:
Monitoring system ; Seismological stations
GCMD keyword(s):
Earthquakes Geophysical stations/networks Seismological stations Seismometers
Funding Reference(s):
European Union’s Horizon 2020 programme for Research and Innovation (727550), Mexican Energy Sustainability Fund CONACYT-SENER (2015-04-68074), Helmholtz-Zentrum Potsdam - Deutsches GeoForschungsZentrum GFZ (GIPP201719)

Station List for Network Code 6G

Code
Station description
Begin
End
Loc
Channels
Flags
DB01
DB01
2017-07-20
2017-09-19
00
HLE HLN HLZ
2017-09-20
2018-12-31
00
HLE HLN HLZ
DB02
DB02
2017-07-20
2017-09-19
00
HLE HLN HLZ
2017-09-20
2018-12-31
00
HLE HLN HLZ
DB05
DB05
2017-09-06
2018-12-31
00
HLE HLN HLZ
DB07
DB07
2017-09-06
2018-12-31
00
HLE HLN HLZ
DB11
DB11
2017-09-13
2018-12-31
00
HLE HLN HLZ
DB12
DB12
2017-09-13
2018-12-31
00
HLE HLN HLZ
DB13
DB13
2017-09-13
2018-12-31
00
HLE HLN HLZ
DB14
DB14
2017-09-14
2018-12-31
00
HLE HLN HLZ
DB15
DB15
2017-09-14
2018-12-31
00
HLE HLN HLZ
DB16
DB16
2017-09-14
2018-12-31
00
HLE HLN HLZ
DB25
DB25
2017-09-30
2018-12-31
00
HLE HLN HLZ
DB27
DB27
2017-10-03
2018-12-31
00
HLE HLN HLZ
DB28
DB28
2017-10-03
2018-12-31
00
HLE HLN HLZ
DB29
DB29
2017-10-03
2018-12-31
00
HLE HLN HLZ
DB31
DB31
2017-10-10
2018-12-31
00
HLE HLN HLZ
DB42
DB42
2017-11-07
2018-02-07
00
HLE HLN HLZ
2018-02-08
2018-12-31
00
HLE HLN HLZ
DB43
DB43
2017-11-21
2018-12-31
00
HLE HLN HLZ
DS03
DS03
2017-09-05
2018-12-31
00
EHE EHN EHZ
DS04
DS04
2017-09-05
2018-12-31
00
EHE EHN EHZ
DS06
DS06
2017-09-06
2018-12-31
00
EHE EHN EHZ
DS08
DS08
2017-09-07
2018-12-31
00
EHE EHN EHZ
DS09
DS09
2017-09-12
2018-12-31
00
EHE EHN EHZ
DS10
DS10
2017-09-12
2018-12-31
00
EHE EHN EHZ
DS20
DS20
2017-09-20
2018-12-31
00
EHE EHN EHZ
DS33
DS33
2017-10-12
2018-12-31
00
EHE EHN EHZ
DS34
DS34
2017-10-12
2018-12-31
00
EHE EHN EHZ
DS45
DS45
2018-04-13
2018-12-31
00
EHE EHN EHZ
SB19
SB19
2017-09-19
2018-12-31
00
HLE HLN HLZ
SB21
SB21
2017-09-20
2018-12-31
00
HLE HLN HLZ
SB22
SB22
2017-09-20
2018-02-14
00
HLE HLN HLZ
2018-02-15
2018-12-31
00
HLE HLN HLZ
SB24
SB24
2017-09-27
2018-12-31
00
HLE HLN HLZ
SB26
SB26
2017-09-30
2018-02-14
00
HLE HLN HLZ
2018-02-15
2018-12-31
00
HLE HLN HLZ
SB30
SB30
2017-10-09
2018-12-31
00
HLE HLN HLZ
SB40
SB40
2017-10-19
2018-12-31
00
HLE HLN HLZ
SB44
SB44
2018-02-09
2018-12-31
00
HLE HLN HLZ
SS17
SS17
2017-09-15
2018-12-31
00
EHE EHN EHZ
SS18
SS18
2017-09-15
2018-12-31
00
EHE EHN EHZ
SS23
SS23
2017-09-27
2018-12-31
00
EHE EHN EHZ
SS32
SS32
2017-10-11
2018-12-31
00
EHE EHN EHZ
SS35
SS35
2017-10-13
2018-12-31
00
EHE EHN EHZ
SS36
SS36
2017-10-13
2018-12-31
00
EHE EHN EHZ
SS37
SS37
2017-10-18
2018-12-31
00
EHE EHN EHZ
SS38
SS38
2017-10-18
2018-12-31
00
EHE EHN EHZ
SS39
SS39
2017-10-19
2018-12-31
00
EHE EHN EHZ
SS41
SS41
2017-11-06
2018-12-31
00
EHE EHN EHZ

Database last updated at 2024 Dec 03 15:00:02